R301.2.1.1 Design criteria. In regions where the basic wind speeds from Figure R301.2(4) equal or exceed 100 miles per hour (45 m/s) in hurricane-prone regions, or 110 miles per hour (49 m/s) elsewhere, the design of buildings shall be in accordance with one of the following methods. The elements of design not addressed by those documents in Items 1 through 4 shall be in accordance with this code.
1. American Forest and Paper Association (AF&PA) Wood Frame Construction Manual for One- and Two-Family Dwellings (WFCM); or
2. International Code Council (ICC) Standard for Residential Construction in High Wind Regions (ICC-600); or
3. Minimum Design Loads for Buildings and Other Structures (ASCE-7); or
4. American Iron and Steel Institute (AISI), Standard for Cold-Formed Steel Framing-Prescriptive Method For One- and Two-Family Dwellings (AISI S230).
5. Concrete construction shall be designed in accordance with the provisions of this code.
6. Structural insulated panel (SIP) walls shall be designed in accordance with the provisions of this code.