ICC Subscriptions
 
SECTION 4.506 INDOOR AIR QUALITY AND EXHAUST

4.506.1 Bathroom exhaust fans.
Mechanical exhaust fans which exhaust directly from bathrooms shall comply with the following:

1. Fans shall be ENERGY STAR compliant and be ducted to terminate outside the building.
2. Unless functioning as a component of a whole house ventilation system, fans must be controlled by a humidistat which shall be readily accessible.

Humidistat controls shall be capable of adjustment between a relative humidity range of 50 to 80 percent.

Note:
For the purposes of this section, a bathroom is a room which contains a bathtub, shower or tub/shower combination.