This table is a cross-reference of the ICC International Residential Code, Chapters 33 through 42, and the 2002 National Electrical Code (NFPA 70-2002).

International Residential Code
National Electrical Code
CHAPTER 33
GENERAL REQUIREMENTS
SECTION E3301
GENERAL
E3301.1
Applicability
None
E3301.2
Scope
Sections 90.1 and 90.2
E3301.3
Not covered
Section 90.2
E3301.4
Additions and alterations
None
SECTION E3302
BUILDING STRUCTURE PROTECTION
E3302.1
Drilling and notching
None
E3302.2
Penetrations of fire-resistance-rated assemblies
Section 300.21
E3302.3
Penetrations of firestops and draftstops
Section 300.21
SECTION E3303
INSPECTION AND APPROVAL
E3303.1
Approval
Section 110.2
E3303.2
Inspection required
None
E3303.3
Listing and labeling
Section 110.3
SECTION E3304
GENERAL EQUIPMENT REQUIREMENTS
E3304.1
Voltages
Section 110.4
E3304.2
Interrupting rating
Section 110.9
E3304.3
Circuit characteristics
Section 110.10
E3304.4
Protection of equipment
Section 110.11
E3304.5
Unused openings
Section 110.12(a)
E3304.6
Integrity of electrical equipment
Section 110.12(c)
E3304.7
Mounting
Section 110.13(a)
E3304.8
Energized parts guarded against accidental contact
Section 110.27(a)
E3304.9
Prevent physical damage
Section 110.27(b)
E3304.10
Equipment identification
Section 110.21
E3304.11
Identification of disconnecting means
Section 110.22
SECTION E3305
EQUIPMENT LOCATION AND CLEARANCES
E3305.1
Working space and clearances
Section 110.26
Figure E3305.1
Working space and clearances
Sections 110.26
Footnote a.
Section 110.26(f)
Footnote b.
Section 110.26(e)
Footnote c.
Section 110.26(b)
Footnote d.
Sections 230.70(a), 240.24(d) and 240.24(e)
Footnote e.
Section 110.26(d)
E3305.2
Working clearances for energized equipment and panelboards
Sections 110.26(a), 110.26(d), and 110.26(f)
E3305.3
Clearances over panelboards
Section 110.26(f)(1)(a)
E3305.4
Location of clear spaces
Sections 110.26(b), 230.70(a) and 240.24
E3305.5
Access and entrance to working space
Section 110.26(c)
E3305.6
Illumination
Section 110.26(d)
E3305.7
Headroom
Section 110.26(e)
SECTION E3306
ELECTRICAL CONDUCTORS AND CONNECTIONS
E3306.1
General
Article 110 and Section 310.1
E3306.2
Conductor material
Section 110.5
E3306.3
Minimum size of conductors
Section 310.5
E3306.4
Stranded conductors
Section 310.3
E3306.5
Individual conductor insulation
Section 310.2(a) and 310.8
E3306.6
Conductors in parallel
Section 310.4
E3306.7
Conductors of the same circuit
Section 300.3(b)
E3306.8
Aluminum and copper connections
Section 110.14
E3306.9
Terminals
Section 110.14(a)
E3306.10
Splices
Section 110.14(b)
E3306.10.1
Continuity
Section 300.13(a)
Exception
Section 300.13(a)
E3306.10.2
Device connections
Sections 250.148 and 300.13(b)
E3306.10.3
Length of conductor for splice or termination
Section 300.14
SECTION E3307
CONDUCTOR AND TERMINAL IDENTIFICATION
E3307.1
Grounded conductors
Sections 200.6(a), 200.6(b) and 310.12(a)
E3307.2
Equipment grounding conductors
Sections 250.119 and 310.12(b)
E3307.3
Ungrounded conductors
Section 310.12(c)
Exception
Section 200.7(c)(2)
E3307.4
Identification of terminals
Section 200.10
E3307.4.1
Device terminals
Section 200.10(a)
E3307.4.2
Receptacles, plugs and connectors
Section 200.10(b)
E3307.5
Tag marking
Section 310.11(b)(3)
CHAPTER 34
ELECTRICAL DEFINITIONS
SECTION E3401
GENERAL
Article 100, Definitions
CHAPTER 35
SERVICES
SECTION 3501
GENERAL SERVICES
E3501.1
Scope
Section 230.1
E3501.2
Number of services
Section 230.2
E3501.3
One building or other structure not to be supplied through another
Section 230.3
E3501.4
Other conductors in raceway or cable
Section 230.7
E3501.5
Raceway seal
Section 230.8
E3501.6
Service disconnect required
Section 230.70
E3501.6.1
Marking of service equipment and disconnects
Sections 230.66 and 230.70(b)
E3501.6.2
Service disconnect location
Sections 230.70(a) and 230.72(c)
E3501.7
Maximum number of disconnects
Section 230.71(a)
SECTION E3502
SERVICE SIZE AND RATING
E3502.1
Rating of ungrounded conductors
Section 230.79(c) and (d)
E3502.2
Service load
Section 220.30
Table E3502.2
Minimum service load calculation
Table 220.30
E3502.2.1
Services under 100 amperes
None
E3502.3
Rating of service disconnect
Section 230.79
E3502.4
Voltage rating
Section 220.30(a)
SECTION E3503
SERVICE, FEEDER AND GROUNDING ELECTRODE CONDUCTOR SIZING
E3503.1
Grounded and ungrounded service conductor size
 310.15(b)(6)
Table E3503.1
Service conductor and grounding electrode conductor sizing
Table 310.16 and Table 250.66
Footnote a.
Section 250.64(e)
Footnotes b and c.
Section 250.64(b)
Footnote d.
Section 250.66(a) and (b)
E3503.2
Ungrounded service conductors for accessory buildings and structures
Section 230.42(b)
Exceptions 1, 2 and 3
Section 230.42(b) and 230.79
E3503.3
Overload protection
Section 230.90
E3503.3.1
Ungrounded conductor
Section 230.90(a)
Exception
Section 230.90(a), Exception No. 3
E3503.3.2
Not in grounded conductor
Section 230.90(b)
E3503.3.3
Location
Section 230.91
E3503.4
Grounding electrode conductor size
Section 250.66
SECTION E3504
OVERHEAD SERVICE DROP AND SERVICE CONDUCTOR INSTALLATION
E3504.1
Clearance from building openings
Section 230.9
Figure E3504.1
Clearances from building openings
Section 230.9
E3504.2
Vertical clearances
Section 230.24
E3504.2.1
Above roofs
Section 230.24(a)
Exception 1
Section 230.24(a), Exception No. 1
Exception 2
Section 230.24(a), Exception No. 2
Exception 3
Section 230.24(a), Exception No. 3
Exception 4
Section 230.24(a), Exception No. 4
Figure E3504.2.1
Clearances from roofs
Section 230.24
E3504.2.2
Vertical clearance from grade
Section 230.24(b)
Items 1, 2 and 3
Section 230.24(b)
E3504.3
Point of attachment
Section 230.26
E3504.4
Means of attachment
Section 230.27
E3504.5
Service masts as supports
Section 230.28
E3504.6
Supports over buildings
Section 230.29
SECTION E3505
SERVICE-ENTRANCE CONDUCTORS
E3505.1
Insulation of service-entrance conductors
Section 230.41
Exceptions 1 and 2
Section 230.41, Exception
E3505.2
Wiring methods for services
Section 230.43
E3505.3
Spliced conductors
Section 230.46
E3505.4
Protection against physical damage
Section 230.49
E3505.5
Protection of service cables against damage
Section 230.50(a)
E3505.6
Direct sunlight exposure
Section 310.8(D)
E3505.7
Mounting supports
Section 230.51
E3505.8
Raceways to drain
Section 230.53
E3505.9
Overhead service locations
Section 230.54
E3505.9.1
Raintight service head
Section 230.54(a)
E3505.9.2
Service cable, service head or gooseneck
Section 230.54(b)
E3505.9.3
Service head location
Section 230.54(c)
Exception
Section 230.54(c), Exception
E3505.9.4
Separately bushed openings
Section 230.54(e)
E3505.9.5
Drip loops
Section 230.54(f)
E3505.9.6
Conductor arrangement
Section 230.54(g)
E3505.9.7
Secured
Section 230.54(d)
SECTION E3506
SERVICE EQUIPMENT—GENERAL
E3506.1
Service equipment enclosures
Section 230.62
E3506.2
Working space
Section 110.26
E3506.3
Available short-circuit current
None
E3506.4
Marking
Section 230.66
SECTION E3507
SYSTEM GROUNDING
E3507.1
System service ground
Sections 250.20(b)(1) and 250.24(a)
E3507.2
Location of grounding electrode conductor connection
Section 250.24(a)(1) and (a)(5)
E3507.3
Two or more buildings or structures supplied from a common service
250.32(a)
Exception
Section 250.32(a), Exception
E3507.3.1
Equipment grounding conductor
Section 250.32(b)(1) and Table 250.122
E3507.3.2
Grounded conductor.
Section 250.32(b)(2)
E3507.4
Grounding electrode conductor
Section 250.24(c)
E3507.5
Main bonding jumper
Section 250.28
E3507.6
Common grounding electrode
Section 250.58
SECTION E3508
GROUNDING ELECTRODE SYSTEM
E3508.1
Grounding electrode system
Section 250.50
E3508.1.1
Metal underground water pipe
Section 250.50(a), 250.53(D)(1), 250.53(E)
E3508.1.2
Concrete-encased electrode
Section 250.50(c)
E3508.2
Made and other electrodes
Section 250.52
E3508.2.1
Rod and pipe electrodes
Section 250.52(c)(1) and (2)
E3508.2.2
Installation
Section 250.52(c)(2)
E3508.2.3
Aluminum electrodes
Section 250.52(b)(1)
E3508.3
Resistance of made electrodes
Section 250.56
E3508.4
Metal underground gas piping system
Section 250.52(b)(2)
SECTION E3509
BONDING
E3509.1
General
Section 250.90
E3509.2
Bonding of service equipment
Section 250.92(a)
E3509.3
Bonding to other systems
Section 250.94
E3509.4
Method of bonding at the service
Section 250.92(b)
E3509.4.1
Grounded service conductor
Section 250.94(1)
E3509.4.2
Threaded connections
Section 250.94(2)
E3509.4.3
Threadless couplings and connectors
Section 250.94(3)
E3509.4.4
Other devices
Section 250.94(4)
E3509.5
Sizing bonding jumper on supply side of service and main bonding jumper
 Section 250.102(c)
E3509.6
Metal water piping bonding
Section 250.104(a)
E3509.7
Bonding other metal piping
Section 250.104(b)
SECTION E3510
GROUNDING ELECTRODE CONDUCTORS
E3510.1
Installation
Section 250.64(a) and (b)
E3510.2
Enclosures for grounding electrode conductors
Section 250.64(e)
SECTION E3511
GROUNDING ELECTRODE CONDUCTOR CONNECTION TO GROUNDING ELECTRODES
E3511.1
Methods of grounding connection to electrodes
Section 250.70
E3511.2
Accessibility
Section 250.68
E3511.3
Effective grounding path
Section 250.68
E3511.4
Protection of ground clamps and fittings
Section 250.10
E3511.5
Clean surfaces
Section 250.12
CHAPTER 36
BRANCH CIRCUIT AND FEEDER REQUIREMENTS
SECTION E3601
GENERAL
E3601.1
Scope
None
E3601.2
Branch-circuit and feeder ampacity
Sections 210.19(A) and 215.2(A)(1)
E3601.3
Selection of ampacity
Section 310.15(A)(2)
E3601.4
Multioutlet branch circuits
Section 210.19(A)(2)
E3601.5
Multiwire branch circuits
Section 210.4
SECTION E3602
BRANCH CIRCUIT RATINGS
E3602.1
Branch-circuit voltage limitations
Sections 210.6(A) and (B)
E3602.2
Branch-circuit ampere rating
Section 210.3
E3602.3
Fifteen- and 20-ampere branch circuits
Section 210.23(A)
E3602.4
Thirty-ampere branch circuits
Section 210.23(b)
E3602.5
Branch circuits serving multiple loads or outlets
Section 210.23(A)
E3602.6
Branch circuits serving a single motor
Section 430.22(A)
E3602.7
Branch circuits serving motor-operated and combination loads
Section 220.4(A)
E3602.8
Branch-circuit inductive lighting loads
Section 220.4(B)
E3602.9
Branch-circuit load for ranges and cooking appliances
Table 220.19, Note 4
E3602.9.1
Minimum branch circuit for ranges
Section 210.19(A)(3)
E3602.10
Branch circuits serving heating loads
Sections 422.13 and 424.3(A)
E3602.11
Branch circuits for air-conditioning and heat pump equipment
Sections 440.35, 440.4(B), 440.52(A)
E3602.12
Branch circuits serving room air conditioners
Section 440.62(A)
E3602.12.1
Where no other loads are supplied
Section 440.62(B)
E3602.12.2
Where lighting units or other appliances are also supplied
Section 440.62(C)
E3602.13
Branch-circuit requirement—summary
Section 210.24 and 210.25
Table E3602.13
Branch-circuit requirement—summary
Table 210.24
SECTION E3603
REQUIRED BRANCH CIRCUITS
E3603.1
Branch circuits for heating
Section 422.12 Exception
E3603.2
Kitchen and dining area receptacles
Section 210.52(B)(1)
E3603.3
Laundry circuit
Sections 210.23(A), Exception and 210.11(C)(2)
E3603.4
Bathroom branch circuits
Section 210.11(C)(3)
E3603.5
Number of branch circuits
Section 210.11(A)
E3603.6
Branch-circuit load proportioning
Section 210.11(B)
SECTION E3604
FEEDER REQUIREMENTS
E3604.1
Conductor size
Table 310.15(B)(6), Sections 215.2(A)(3), (A)(4), and 220.10(A)
E3604.2
Minimum feeder conductor size
Section 215.2(A)(2)
E3604.3
Feeder loads
Table 220.11
Table E3604.3(1)
Feeder load calculation
Table 220.11, Table 220.30(C), Sections 220.14, 220.15, 220.17, 220.18 and 220.19
Table E3604.3(2)
Demand loads for electric ranges, wall-mounted ovens, counter-mounted cooking units and other cooking appliances over 13/4 kVA rating
Table 220.19
E3604.4
Feeder neutral load
Section 220.22
E3604.5
Lighting and convenience receptacle load
Section 220.3(A), Table 220.3(A)
E3604.6
Ampacity and computed loads
Section 220.10
E3604.7
Feeder and branch-circuit conductors
Section 240.21(A)
SECTION E3605
CONDUCTOR SIZING AND OVERCURRENT PROTECTION
E3605.1
General
310.15(a)
Table E3605.1
Allowable ampacities
Table 310.16 and 240.4(D)
E3605.2
Correction factors for ambient temperatures
Table 310.16
Table E3605.2
Ambient temperature correction factors
Table 310.16, Correction factors
E3605.3
Adjustment for conductor proximity
Section 310.15(B)(2)(a)
Table E3605.3
Conductor proximity adjustment factors
Table 310.15(B)(2)(a)
E3605.4
Temperature limitations
Section 110.14(C)
E3605.4.1
Conductors rated 60°C.
Section 110.14(C)(1)(a)
E3605.4.2
Conductors rated 75°C.
Section 110.14(C)(b)
E3605.4.3
Separately installed pressure connectors
Section 110.14(C)(2)
E3605.4.4
Conductors of type NM cable
Section 334.8(D) and 334.112
E3605.5
Overcurrent protection required
Table 310.15(B)(6), Sections 240.4, 240.5, 240.21
E3605.5.1
Cords
Section 240.5
E3605.5.2
Overcurrent devices of the next higher size
Section 240.4(B)
E3605.5.3
Small conductors
Section 240.4(D)
E3605.5.4
Air conditioning and heat pump equipment
Section 240.4(G)
E3605.6
Fuses and fixed trip circuit breakers
Section 240.6
E3605.7
Location of overcurrent devices in or on premises
Section 240.24(A)(C)(D)(E)
E3605.8
Ready access for occupants
Section 240.24(B)
E3605.9
Enclosures for overcurrent devices
Section 240.30(A)(B)
SECTION E3606
PANELBOARDS
E3606.1
Panelboard rating
Section 408.13
E3606.2
Panelboard circuit identification
Section 408.4
E3606.3
Panelboard overcurrent protection
Section 408.16(A)
CHAPTER 37
WIRING METHODS
SECTION E3701
GENERAL REQUIREMENTS
E3701.1
Scope
Section 300.1
E3701.2
Allowable wiring methods
Sections 110.8 and 300.3
Table E3701.2
Allowable wiring methods
None
E3701.3
Circuit conductors
Section 300.3(B)
E3701.4
Wiring method applications
Chapter 3 and Section 300.2
Table E3701.4
Allowable applications for wiring methods
Chapter 3 and Section 300.2
SECTION E3702
ABOVEGROUND INSTALLATION REQUIREMENTS
E3702.1
Installation and support requirements
Chapter 3 
Table E3702.1
General installation and support requirements for wiring methods
Chapter 3 
E3702.2
Cables in accessible attics
Sections 320.23 and 334.23
E3702.2.1
Across structural members
Sections 320.23(A) and 334.23
E3702.2.2
Cable installed parallel to framing members
Sections 320.17, 320.23(A), 334.17 and 334.23
E3702.3
Exposed cable
Sections 320.15 and 334.15
E3702.3.1
Surface installation
Section 334.15
E3702.3.2
Protection from physical damage
Section 334.15(B)
E3702.3.3.3
Location exposed to direct sunlight
Section 310.8(D)
E3702.4
In unfinished basements
Section 334.15(C)
E3702.5
Bends
Sections 320.24 and 334.24
SECTION E3703
UNDERGROUND INSTALLATION REQUIREMENTS
E3703.1
Minimum cover requirements
Section 300.5(A)
Table E3703.1
Minimum cover requirements, burial in inches
Table 300.5
E3703.2
Warning ribbon
Section 300.5(D)(3)
E3703.3
Grounding
Section 300.5(B)
E3703.4
Protection from damage
Section 300.5(D)
E3703.5
Splices and taps
Section 300.5(E)
E3703.6
Backfill
Section 300.5(F)
E3703.7
Raceway seals
Section 300.5(G)
E3703.8
Bushing
Section 300.5(H)
E3703.9
Single conductors
Section 300.5(I)
E3703.10
Ground movement
Section 300.5(J)
CHAPTER 38
POWER AND LIGHTING DISTRIBUTION
SECTION E3801
RECEPTACLE OUTLETS
E3801.1
General
Section 210.50 and 210.52
E3801.2
Convenience receptacle distribution
Section 210.52(A)
E3801.2.1
Spacing
Section 210.52(A)(1)
E3801.2.2
Wall space
Section 210.52(A)(2)
E3801.2.3
Floor receptacles
Section 210.52(A)(3)
E3801.3
Small appliance receptacles
Section 210.52(B)
E3801.3.1
Other outlets prohibited
Section 210.52(B)(2)
E3801.3.2
Limitations
Section 210.52(B)(3)
E3801.4
Countertop receptacles
Section 210.52(C)
E3801.4.1
Wall counter space
Section 210.52(C)(1)
E3801.4.2
Island counter spaces
Section 210.52(C)(2)
E3801.4.3
Peninsular counter space
Section 210.52(C)(3)
E3801.4.4
Separate spaces
Section 210.52(C)(4)
E3801.4.5
Receptacle outlet location
Section 210.52(C)(5)
E3801.5
Appliance outlets
Section 210.50(C)
E3801.6
Bathroom and toilet room
Section 210.52(D)
E3801.7
Outdoor outlets
Section 210.52(E)
E3801.8
Laundry areas
Section 210.52(F)
E3801.9
Basements and garages
Section 210.52(G)
E3801.10
Hallways
Section 210.52(H)
E3801.11
HVAC outlet
Section 210.63
SECTION E3802
GROUND-FAULT AND ARC-FAULT CIRCUIT-INTERRUPTER PROTECTION
E3802.1
Bathroom receptacles
Section 210.8(A)(1)
E3802.2
Garage receptacles
Section 210.8(A)(2)
E3802.3
Outdoor receptacles
Section 210.8(A)(3)
E3802.4
Crawl space receptacles
Section 210.8(A)(4)
E3802.5
Unfinished basement receptacles
Section 210.8(A)(5)
E3802.6
Kitchen receptacles
Section 210.8(A)(6)
E3802.7
Bar sink receptacles
Section 210.8(A)(7)
E3802.8
Boathouse receptacles
Section 210.8(A)(8)
E3802.9
Electrically heated floors
Section 424.44(G)
E3802.10
Exempt receptacles
Section 210.8(A)(2)
E3802.11
Bedroom outlets
Section 210.12(B)
SECTION E3803
LIGHTING OUTLETS
E3803.1
General
Section 210.70(A)
E3803.2
Habitable rooms
Section 210.70(A)(1)
E3803.3
Additional locations
Section 210.70(A)(2)
E3803.4
Storage or equipment spaces
Section 210.70(A)(3)
SECTION E3804
GENERAL INSTALLATION REQUIREMENTS
E3804.1
Electrical continuity of metal raceways and enclosures
Section 300.10
E3804.2
Mechanical continuity—raceways and cables
Section 300.12
E3804.3
Securing and supporting
Section 300.11(A)
E3804.4
Raceways as means of support
Section 300.11(B)
E3804.5
Raceway installations
Section 300.18
E3804.6
Conduit and tubing fill
Section 300.17 and Chapter 9, Table 1
Tables E3804.6(1)-E3804.6(10)
Maximum number of conductors in conduit or tubing
Section 300.17 and Chapter 9, Table 1, Note 1
E3804.7
Air handling—stud cavity and joist spaces
Section 300.22(C), Exception
SECTION E3805
BOXES, CONDUIT BODIES AND FITTINGS
E3805.1
Box, conduit body or fitting—where required
Section 300.15
E3805.1.1
Equipment
Section 300.15(B)
E3805.1.2
Protection
Section 300.15(C)
E3805.1.3
Integral enclosure
Section 300.15(E)
E3805.1.4
Fitting
Section 300.15(F)
E3805.1.5
Buried conductors
Section 300.15(G)
E3805.1.6
Fixtures
Section 300.15(J)
E3805.1.7
Closed loop
Section 300.15(M)
E3805.2
Metal boxes
Section 314.4
E3805.3
Nonmetallic boxes
Section 314.3
E3805.3.1
Nonmetallic-sheathed cable and nonmetallic boxes
Section 314.17(C)
E3805.3.2
Securing to box
Section 314.17(C)
E3805.3.3
Conductor rating
Section 314.17(C)
E3805.4
Minimum depth of outlet boxes
Section 314.24
E3805.5
Boxes enclosing flush-mounted devices
Section 314.19
E3805.6
Boxes at luminaire (lighting fixture) outlets
Section 314.27(A)
E3805.7
Maximum luminaire (fixture) weight
Section 314.27(B)
E3805.8
Floor boxes
Section 314.27(C)
E3805.9
Boxes at fan outlets
Section 314.27(C)
E3805.10
Conduit bodies, junction, pull and outlet boxes to be accessible
Section 314.29
E3805.11
Damp or wet locations
Section 314.15(A)
E3805.12
Number of conductors in outlet, device, and junction boxes, and conduit boxes
Section 314.16
 E3805.12.1
Box volume calculations
Section 314.16(A)
Table E3805.12.1
Maximum number of conductors in metal boxes
Table 314.16
E3805.12.1.1
Standard boxes
Section 314.16(A)
E3805.12.1.2
Other boxes
Section 314.16(A)(2)
E3805.12.2
Box fill calculations
Section 14.16(B)
E3805.12.2.1
Conductor fill
Section 314.16(B)(1), Table 314.16
Table E3805.12.2.1
Volume allowance required per conductor
Table 314.16
E3805.12.2.2
Clamp fill
Section 314.16(B)(2)
E3805.12.2.3
Support fittings fill
Section 314.16(B)(3)
E3805.12.2.4
Device or equipment fill
Section 314.16(B)(4)
E3805.12.2.5
Equipment grounding conductor fill
Section 314.16(B)(5)
E3805.12.3
Conduit bodies
Section 314.16(C)
E3805.12.3.1
Splices, taps or devices
Section 314.16(C)(2)
SECTION E3806
INSTALLATION OF BOXES, CONDUIT BODIES AND FITTINGS
E3806.1
Conductors entering boxes, conduit bodies or fittings
Section 314.17
E3806.1.1
Insulated fittings
Section 300.4(F)
E3806.2
Openings
Section 314.17(A), 110.12(A)
E3806.3
Metal boxes, conduit bodies and fittings
Section 314.17, 314.17(B)
E3806.4
Unused openings
Section 314.17, 110.12(A)
E3806.5
In wall or ceiling
Section 314.20
E3806.6
Plaster, gypsum board and plasterboard
Section 314.21
E3806.7
Exposed surface extensions
Section 314.22
E3806.8
Supports
Section 314.23
E3806.8.1
Surface mounting
Section 314.23(A)
E3806.8.2
Structural mounting
Section 314.23(B)
E3806.8.2.1
Nails
Section 314.23(B)(1)
E3806.8.2.2
Braces
Section 314.23(B)(2)
E3806.8.3
Mounting in finished surfaces
Section 314.23(C)
E3806.8.4
Raceway supported enclosures without devices or fixtures
Section 314.23(E)
E3806.8.5
Raceway supported enclosures, with devices or fixtures
Section 314.23(F)
E3806.8.6
Enclosures in concrete or masonry
Section 314.23(G)
E3806.9
Covers and canopies
Section 314.25
E3806.10
Metal covers and plates
Section 314.25(A)
E3806.11
Exposed combustible finish
Section 314.25(B)
SECTION E3807
CABINETS AND PANELBOARDS
E3807.1
Enclosures for switches or overcurrent devices
Section 312.8
E3807.2
Damp or wet locations
Section 312.2(A)
E3807.3
Position in wall
Section 312.3
E3807.4
Unused openings
Section 312.5(A), 110.12(A)
E3807.5
Conductors entering cabinets
Sections 300.4(F) and 312.5(B)
E3807.6
Openings to be closed
Section 312.5(A)
E3807.7
Cables
Section 312.5(B)
SECTION E3808
GROUNDING
E3808.1
Metal enclosures
Section 250.86, 250.110(1)
E3808.2
Equipment fastened in place or connected by permanent wiring methods (fixed)
Section 250.110(I)
E3808.3
Specific equipment fastened in place or connected by permanent wiring methods
Section 250.112(J), (L)
E3808.4
Performance of fault current path
Section 250.4(A)(5)
E3808.5
Earth as a grounding conductor
Section 250.4(A)(5)
E3808.6
Load-side neutral
Section 250.142(B)
E3808.7
Load-side equipment
Section 250.142(B)
E3808.8
Types of equipment grounding conductors
Section 250.118
E3808.8.1
Flexible metal conduit
Section 250.118(6)
E3808.8.2
Liquidtight flexible metal conduit
Section 250.118(7)
E3808.8.3
Nonmetallic sheathed cable (Type NM)
Section 334.10(B)
E3808.9
Equipment fastened in place or connected by permanent wiring methods
Section 250.134
E3808.10
Methods of equipment grounding
Section 250 Part (VII)
E3808.11
Equipment grounding conductor installation
Section 250.120
E3808.12
Equipment grounding conductor size
Section 250.122
Table E3808.12
Equipment grounding conductor sizing
Table 250.122
E3808.12.1
Multiple circuits
Section 250.122(C)
E3808.13
Continuity and attachment of branch-circuit equipment grounding conductors to boxes
 Section 250.148
E3808.14
Connecting receptacle grounding terminal to box
Section 250.146
E3808.15
Metal boxes
Section 250.148(A)
E3808.16
Nonmetallic boxes
Section 250.148(B)
E3808.17
Clean surfaces
Section 250.12
E3808.18
Bonding other enclosures
Section 250.96(A)
E3808.19
Size of equipment bonding jumper on load side of service
Section 250.102(D)
E3808.20
Installation—equipment bonding jumper
Section 250.102(E)
SECTION E3809
FLEXIBLE CORDS
E3809.1
Where permitted
Sections 400.7 and 400.8
E3809.2
Loading and protection
Section 400.5
Table E3809.2
Maximum ampere load and overcurrent-protection-device rating for flexible cords
Section 240.4, Tables 400.5(A) and 240.5(B)(1)
E3809.3
Splices
Section 400.9
E3809.4
Attachment plugs
Section 400.7(B)
CHAPTER 39
DEVICES AND LIGHTING FIXTURES
SECTION E3901
SWITCHES
E3901.1
Rating and application of snap switches
Section 404.14(A)
E3901.2
CO/ALR snap switches
Section 404.14(C)
E3901.3
Indicating
Section 404.7
E3901.4
Time switches and similar devices
Section 404.5
E3901.5
Grounding of enclosures
Section 404.12
E3901.6
Access
Section 404.4
E3901.7
Wet locations
Section 404.8
E3901.8
Grounded conductors
Section 404.2(B)
E3901.9
Switch connections
Section 404.2(A)
E3901.10
Box mounted
Section 404.10(B)
E3901.11
Snap switch faceplates
Section 404.9(A)
E3901.11.1
Faceplate grounding
Section 404.9(B)
SECTION E3902
RECEPTACLES
E3902.1
Rating and type
Section 406.2(A), (B)
E3902.1.1
Single receptacle
Section 210.21(B)(1)
E3902.1.2
Two or more receptacles
Section 210.21(B)(3)
Table E3902.1.2
Receptacle ratings for various size multioutlet circuits
Section 210.21
E3902.2
Grounding type
Section 406.3(A)
E3902.3
CO/ALR receptacles
Section 406.2(C)
E3902.4
Faceplates
Section 406.5(B)
E3902.5
Position of receptacle faces
Section 406.4(D)
E3902.6
Receptacles mounted in boxes
Sections 406.4, 406.4(A), 406.5
E3902.7
Receptacles mounted on covers
Section 406.4(C)
E3902.8
Damp locations
Section 406.8(A)
E3902.9
Wet locations
Section 406.8(B)
E3902.10
Bathtub and shower space
Section 406.8(C)
E3902.11
Flush mounting with faceplate
Section 406.8(E)
E3902.12
Outdoor installation
Section 406.8
SECTION E3903
FIXTURES
E3903.1
Energized parts
Section 410.3
E3903.2
Fixtures near combustible material
Section 410.5
E3903.3
Exposed conductive parts
Section 410.18(A)
E3903.4
Screw-shell type
Section 410.47
E3903.5
Recessed incandescent fixtures
Section 410.65(C)
E3903.6
Thermal protection
Section 410.73(E)
E3903.7
High-intensity discharge fixtures
Section 410.73(F)
E3903.8
Wet or damp locations
Section 410.4(A)
E3903.9
Lampholders in wet or damp locations
Section 410.49
E3903.10
Pendants
Section 410.4(D)
E3903.11
Fixtures in clothes closets
Section 410.8(A)
Figure E3903.11
Closet storage space
Figure 410.8
E3903.12
Fixture wiring—general
Section 410.22
E3903.12.1
Polarization of fixtures
Section 410.23
E3903.12.2
Fixtures as raceways
Section 410.31
SECTION E3904
FIXTURE INSTALLATION
E3904.1
Outlet box covers
Section 410.12
E3904.2
Combustible material at outlet boxes
Section 410.13
E3904.3
Access
Section 410.16(B)
E3904.4
Supports
Section 410.15(A)
E3904.5
Means of support
Sections 410.16, 314.27(B), 410.15(A)
E3904.6
Exposed ballasts
Section 410.76(A)
E3904.7
Combustible low-density cellulose fiberboard
Section 410.76(B)
E3904.8
Recessed fixture clearance
Section 410.66(A)(1), (A)(2)
E3904.9
Recessed fixture installation
Section 410.66(B)
SECTION E3905
TRACK LIGHTING
E3905.1
Installation
Section 410.101(A)
E3905.2
Connected load
Section 410.101(B)
E3905.3
Locations not permitted
Section 410.101(C)
E3905.4
Support
Section 410.101(D)
E3905.5
Fastening
Section 410.104
E3905.6
Grounding
Section 410.105(B)
CHAPTER 40
APPLIANCE INSTALLATION
SECTION E4001
GENERAL
E4001.1
Scope
Sections 422.1 and 424.1
E4001.2
Installation
Sections 110.3(B) and 422.17
E4001.3
Flexible cords
Section 422.16
Table E4001.3
Flexible cord length
Sections 422.16(B)(1) and (2)
E4001.4
Overcurrent protection
Section 422.11
E4001.4.1
Single motor-operated appliance
Section 422.11(E)
E4001.5
Disconnecting means
Sections 422.30, 422.35 and 424.19
Table E4001.5
Disconnecting means
Sections 422.31(A), (B), 422.35, 424.19, 424.20, and 440.14
E4001.6
Ceiling fans
Section 422.18
E4001.7
Snow-melting and deicing equipment protection
Section 210.8(a)(3) Exception and 426.28
CHAPTER 41
SWIMMING POOLS
SECTION E4101
GENERAL
E4101.1
Scope
Section 680.1
E4101.2
Definitions
Section 680.2
SECTION E4102
WIRING METHODS FOR POOLS, SPAS, HOT TUBS AND HYDROMASSAGE BATHTUBS
E4102.1
General
Sections 608.7, 680.23(B), 680.21(C), 680.23(F), 680.21(A), 680.40, 680.42 and 680.43
 E4102.2
Flexible cords
Sections 680.22(B)(5), 680.7(A), (B), 680.42 and 680.21(F)(1)
SECTION E4103
EQUIPMENT LOCATION AND CLEARANCES
E4103.1
Receptacle outlets
Section 680.22(A)(6)
E4103.1.1
Location
Section 680.22(A)(1)
E4103.1.2
Where required
Section 680.22(A)(3)
E4103.1.3
GFCI protection
Section 680.22(A)(5)
E4103.1.4
Indoor locations
Section 680.43(A) and (A)(1)
E4103.1.5
Indoor GFCI protection
Sections 680.43(A)(2), 680.71
E4103.2
Switching devices
Sections 680.22(C), 680.43(C), 680.72
E4103.3
Disconnecting means
Section 680.12
E4103.4
Luminaires and ceiling fans
Section 680.22(B)
E4103.4.1
Outdoor location
Section 680.22(B)
E4103.4.2
Indoor location
Section 680.22(B)(2)
E4103.4.3
Existing lighting outlets and luminaires
680.22(B)(3)
E4103.4.4
Indoor spas and hot tubs
Section 680.43(B)
E4103.4.5
GFCI protection
Section 680.22(B)(4)
E4103.5
Overhead conductor clearances
Section 680.8
Table E4103.5
Overhead conductor clearances
Table 680.8
Figure E4103.5
Overhead conductor clearances
Figure 680.8
E4103.6
Underground wiring
Section 680.10
Table E4103.6
Minimum burial depths
Section 680.10
SECTION E4104
BONDING
E4104.1
Bonded Parts
Sections 680.26(B), 680.42(B) and 680.43(D)(4)
E4104.2
Parts not required to be bonded
Sections 680.42(B) and 680.43(D)(4) Exception
E4104.3
Methods of bonding
Sections 680.26(B)(4), 680.26(C), 680.42(B) and 680.43(E)
SECTION E4105
GROUNDING
E4105.1
Equipment to be grounded
Section 680.26
E4105.2
Luminaires
Section 680.23(F)(1), (2)
E4105.3
Nonmetallic conduit
Section 680.23(B)(1), 680.23(B)(2)(b)
E4105.4
Flexible cords
Section 680.23(B)(3)
E4105.5
Motors
Section 680.21(A)(1)
E4105.6
Panelboards
Section 680.25(B), (B)(1)
E4105.7
Cord-connected equipment